Device name: Shelly EM Gen3
Device model: S3EM-002CXCEU
Device SSID: ShellyEMG3-XXXXXXXXXXXX
BLE Model ID: 0x1027
Shelly EM Gen3 (the Device) is a small form factor smart energy meter using up to 2 current transformers (contactless metering), which allows energy metering the consumption of electric appliances and reporting to a mobile phone, tablet, PC, or home automation system. It can work standalone in a local Wi-Fi network or it can also be operated through cloud home automation services. The Device has internal storage for data allowing for later retrieval. The Device has single dry contact switch for controlling external loads.
Shelly EM Gen3 can be accessed, controlled, and monitored remotely from any place where the User has internet connectivity, as long as the device is connected to a Wi-Fi access point and the Internet.
Shelly EM Gen3 can be retrofitted into standard electrical wall boxes, next to electrical appliances, power sockets, or in other places with limited installation space.
Shelly EM Gen3 has an embedded Web Interface which can be used to monitor, configure, and control the device.
Compact form factor
Single phase, two channels measurment
Current transformer connection
Dry contact relay for contactor control
Real-time clock
Data logs stored on device for up to 10 days of minute data records
Power Consumption Monitoring: Monitor the power consumption of connected devices in real-time. This information can be valuable for understanding energy usage patterns and making informed decisions to reduce consumption.
Energy Efficiency Optimization: Identify electrical energy consumption patterns and optimize electricity usage.
Appliance Health Check: Keep track of the power usage of individual appliances to assess their health and performance over time. Sudden spikes or changes in power consumption may indicate issues with the appliance.
Cost Management: With the knowledge of power consumption, you can estimate the cost of running specific devices and manage your electricity expenses more effectively.
Space-Efficient Retrofitting: Integrate the device into standard electrical wall boxes, behind power sockets, light switches, or other locations with limited space.
Remote Monitoring: Shelly EM Gen3 supports publishing data to Shelly cloud or other cloud based data collection and storage systems. This allows you to monitor power consumption even when you're away from home.
Local Monitoring: Like the rest of the Shelly Wi-Fi line of devices Shelly EM Gen3 allows for local only monitoring and automations. Access stored energy consumption records directly from the device UI. Automate locally with rules based on instantaneous power consumption or energy consumer for a period of time.
Residential
MDU (Multi Dwelling Units - apartments, condominiums, hotels, etc.)…
Light commercial (small office buildings, small retail/restaurant/gas station, etc.)…
Industrial (factories, power plants, water processing, refineries, etc.)…
Government/municipal
University/college
Farming

Wi-Fi
Bluetooth
MQTT
HTTP
WebSocket
RPC
Internal temperature sensing and reporting
Resistive (incandescent bulbs, heating devices)
Capacitive (LED light drivers, capacitor banks, electronic equipment, motor start capacitors)
Inductive (transformers, fans, refrigerators, air-conditioners)
One (Control) button
Press and hold for 5 seconds to enable Device access point and Bluetooth connection.
Press and hold for 10 seconds to factory reset the Device.
LED (monocolor) indication
AP (Access Point) enabled and Wi-Fi disabled:
1 second ON / 1 second OFF
Wi-Fi enabled, but not connected to a Wi-Fi network:
1 second ON / 3 seconds OFF
Connected to a Wi-Fi network:
Constantly ON
Cloud is enabled, but not connected:
1 second ON /5 seconds OFF
Connected to Shelly Cloud:
Constantly ON
OTA (Over the Air Update):
½ sec ON / ½ second OFF
Button pressed and held for 5 seconds:
½ second ON / ½ second OFF
Button presses and held for 10 seconds:
¼ second ON / ¼ second OFF
The list above starts with the initial device status and the lowest priority. Every next state cancels the previous one.
|
Quantity |
Value |
|---|---|
|
Physical |
|
|
Size (HxWxD): |
37x42x16 mm / 1.46x1.65x0.63 inch |
|
Weight: |
|
|
Screw terminals max torque: |
0.4 Nm / 3.5 lbin |
|
Conductor cross section: |
0.2 to 2.5 mm² / 24 to 14 AWG (solid, stranded, and bootlace ferrules) |
|
Conductor stripped length: |
6 to 7 mm / 0.24 to 0.28 in |
|
Mounting: |
Wall console, Electrical cabinet |
|
Shell material: |
Plastic |
|
Shell color: |
|
|
Connectors color: |
Black |
|
Environmental |
|
|
Ambient working temperature: |
-20 °C to 40 °C / -5 °F to 105 °F |
|
Humidity: |
30 % to 70 % RH |
|
Max. altitude: |
2000 m / 6562 ft |
|
Electrical |
|
|
Power supply: |
110 - 240 V~ 50/60 Hz |
|
Power consumption: |
< 1.2 W |
|
Neutral not needed: |
Yes or No |
|
External protection: |
2 A, tripping characteristic B or C, |
|
Output circuits ratings |
|
|
Max. switching voltage: |
240 V~ |
|
Max. switching current: |
2 A/240 V~ |
|
Sensors, meters |
|
|
Voltmeter (AC): |
110-240 V~ 50/60 Hz |
|
Voltmeter accuracy: |
±2% |
|
Ammeter (AC): |
0 - 80A |
|
Ammeter accuracy: |
±2 % (2 - 50 A), ±2 % (1 - 2 A), ±5 % (0 - 1 A) |
|
Compatible current transformers: |
|
|
Power and energy meters: |
|
|
Channel-to-channel calibration minimum load: |
500 W |
|
No load threshold: |
30 VA per channel |
|
Measurement data storage: |
At least 10 days of 1 min data resolution |
|
Data export: |
|
|
Internal-temperature sensor: |
Yes |
|
Radio |
|
|
Wi-Fi |
|
|
Protocol: |
802.11 b/g/n |
|
RF band: |
2412 - 2472 МHz |
|
Max. RF power: |
< 20 dBm |
|
Range: |
Up to 30 m / 100 ft indoors and 50 m / 160 ft outdoors |
|
Bluetooth |
|
|
Protocol: |
4.2 |
|
RF band: |
2402 - 2480 MHz |
|
Max. RF power: |
< 4 dBm |
|
Range: |
Up to 10 m / 33 ft indoors and 30 m / 100 ft outdoors |
|
Microcontroller unit |
|
|
CPU: |
ESP-Shelly-C38F |
|
Flash: |
8 MB |
|
Firmware capabilities |
|
|
Schedules: |
Yes |
|
Webhooks (URL actions): |
20 with 5 URLs per hook |
|
Scripting: |
Yes |
|
MQTT: |
Yes |
|
Encryption: |
Yes (Transport level) |
|
Authentication: |
Yes (Application and transport level) |

Legend
|
Terminals |
Wires |
||
|---|---|---|---|
|
O |
Load circuit output terminal |
L |
Live (110-240 V) wire |
|
I |
Load circuit input terminal |
N |
Neutral wire |
|
IA |
First channel current transformer input |
Current transformers |
|
|
IB |
Second channel current transformer input |
CTA |
First channel current transformer |
|
L |
Live (110-240 V) terminal |
CTB |
Second channel current transformer |
|
N |
Neutral terminal |
|
|
©2026 Securityshop.lt | UAB DEALER1