  • Type: Residual current circuit breaker with overcurrent protection (RCBO)
  • Model: Hager AD966J
  • Number of poles: 2P (1P+N)
  • Rated current: 16 A
  • Tripping characteristic: C
  • Type: AC (for alternating current)
  • Short-circuit capacity: 6 kA
  • Brand: Hager
€55.41
Tax included Delivery within 1–3 business days
Quantity

  • General
  • Pole configuration1P+N
  • Tripping curveC
  • Rated current16 A
  • Rated residual operating current Idn30 mA
  • Rated current at –25 °C18.50 A
  • Rated current at –20 °C18.30 A
  • Rated current at –15 °C18.10 A
  • Rated current at –10 °C17.90 A
  • Rated current at –5 °C17.70 A
  • Rated current at 0 °C17.40 A
  • Rated current at 5 °C17.20 A
  • Rated current at 10 °C17.00 A
  • Rated current at 15 °C16.70 A
  • Rated current at 20 °C16.50 A
  • Rated current at 25 °C16.20 A
  • Rated current at 30 °C16.00 A
  • Rated current at 35 °C15.80 A
  • Rated current at 40 °C15.60 A
  • Rated current at 50 °C15.20 A
  • Rated current at 55 °C15.00 A
  • Rated current at 60 °C14.80 A
  • Correction factor for 2 devices side by side1.00
  • Correction factor for 3 devices side by side0.95
  • Correction factor for 4–5 devices side by side0.90
  • Correction factor for 6 devices side by side0.85
  • Thermal operation threshold (AC)1.13–1.45 A
  • Rated short-circuit breaking capacity Icn (230 V AC, IEC 60898-1)6 kA
  • Residual current typeA
  • Ingress Protection (IP) classIP2X
  • Rated short-circuit breaking capacity Icn AC (IEC 60898-1)6 kA
  • Connection typeScrew terminal
  • Rated insulation voltage Ui500 V
  • Rated impulse withstand voltage Uimp4,000 V
  • Maximum operating voltage240 V
  • Rated operational voltage Ue240 V
  • Overvoltage category (IEC 60947-1)3
  • Total power loss at In5.20 W
  • Frequency50 Hz
  • Max. altitude2,000 m
  • Energy limitation class I²t3
  • Operating temperature–25 to +40 °C
  • Storage/transport temperature–25 to +70 °C
  • Electrical endurance2,000 cycles
  • Mechanical endurance2,000 operations
  • Conductor cross-section (flexible)1–16 mm²
  • Conductor cross-section (rigid)1–25 mm²
  • Input with screws (flexible conductor)1–16 mm²
  • Input with screws (rigid conductor)1–25 mm²
  • Output with screws (flexible conductor)1–16 mm²
  • Output with screws (rigid conductor)1–25 mm²
  • Input/output with screws (flexible conductor)1–16 mm²
  • Input/output with screws (rigid conductor)1–25 mm²
  • Nominal tightening torque2.10 Nm
  • Top connection type (modular devices)Screw terminal
  • Bottom connection type (modular devices)Biconnect
  • Number of modules2
  • Height83 mm
  • Width35 mm
  • Depth68 mm