New

Circuit breaker Hager NDN116 (1P, 16A, D, 10kA, 400V)

SKU:HNDN116
On Stock
  • Type: Circuit breaker
  • Model: Hager NDN116
  • Number of poles: 1P
  • Rated current: 16 A
  • Tripping characteristic: D
  • Short-circuit capacity: 10 kA
  • Voltage: 400 V
  • Brand: Hager
€8.99
Tax included Delivery within 1–3 business days
Quantity

  • General
  • Rated current16 A
  • Rated service short-circuit breaking capacity Ics (230 V AC, IEC 60947-2)7.50 kA
  • Rated short-circuit breaking capacity Icn (230 V AC, IEC 60898-1)10 kA
  • Rated ultimate short-circuit breaking capacity Icu (230 V AC, IEC 60947-2)15 kA
  • Rated current at –25 °C20.49 A
  • Rated current at –20 °C20.12 A
  • Rated current at –15 °C19.75 A
  • Rated current at –10 °C19.37 A
  • Rated current at –5 °C18.98 A
  • Rated current at 0 °C18.58 A
  • Rated current at 5 °C18.18 A
  • Rated current at 10 °C17.76 A
  • Rated current at 15 °C17.34 A
  • Rated current at 20 °C16.90 A
  • Rated current at 25 °C16.46 A
  • Rated current at 30 °C16.00 A
  • Rated current at 35 °C15.53 A
  • Rated current at 40 °C15.04 A
  • Rated current at 45 °C14.54 A
  • Rated current at 50 °C14.02 A
  • Rated current at 55 °C13.48 A
  • Rated current at 60 °C12.91 A
  • Rated current at 65 °C12.32 A
  • Rated current at 70 °C11.70 A
  • Pole type1P
  • Tripping curveD
  • Number of modules1
  • Rated short-circuit breaking capacity Icn (IEC 60898-1)10 kA
  • Nominal tightening torque (top terminal)2.80 Nm
  • Nominal tightening torque (bottom terminal)2.80 Nm
  • Nominal tightening torque (general)2.80 Nm
  • Bottom connection type (modular devices)Biconnect
  • Top connection type (modular devices)Screw terminal
  • 360° mounting positionYes
  • Rated operational voltage Ue230–400 V AC
  • Rated insulation voltage Ui500 V
  • Rated impulse withstand voltage Uimp6,000 V
  • Frequency50–60 Hz
  • Input/output cross-section (rigid conductors)1–35 mm²
  • Input/output cross-section (flexible conductors)1–25 mm²
  • Ingress Protection (IP) classIP20
  • Pollution degree (IEC 60664 / IEC 60947-2)2
  • Operating temperature–25 to +70 °C
  • Total power loss at In2.62 W
  • Electrical endurance (switching cycles)4,000
  • Mechanical endurance (switching cycles)20,000
  • Connection typeScrew terminal
  • Top connection alignment (modular devices)Aligned terminals
  • Bottom connection alignment (modular devices)Aligned terminals
  • Height83 mm
  • Width17.5 mm
  • Depth70 mm
HNDN116
check Product added to compare.